cens logo
CONVERSION MODULE KITS(T5)

CONVERSION MODULE KITS(T5)

Model:
WA33-36

Detail Specifications / Descriptions

Model
WA33-36
WA43-58
WA43-36
WA53-70
WA53-35


Feaures
 
 
 
 
 


Lsw/Lch Interlock
Not for H.f.
Not for H.f.
V
V
V


Cathode heating
-
-
-
-
V


5 Pole Relay
4 Pole Relay
4 Pole Relay
V
V
V


Technical:
 
 
 
 
 


Battery
Voltage/Capacity
3.6Vdc 4.0Ah Ni-cd
4.8Vdc 4.0Ah Ni-cd
4.8Vdc 4.0Ah Ni-cd
6.0Vdc 4.0Ah Ni-cd
6.0Vdc 4.0Ah Ni-cd


Duration
3 hours
3 hours
3 hours
3 hours
3 hours


Battery Format
3 cells
2 cells + 2 cells
2 cells + 2 cells
3 cells + 3 cells
3 cells + 3 cells


Lamp range and BLF
(Ballast Lumen Factor) [Please note that Amalgam lamps may not be suitable for
emergency lighting use.] :
8W T5 0.19
11W PLS 0.20
13W
PL 0.17
18W T8/PL0.12
24/26W PL0.10
36W T8/PL0.08
18W T8 0.14
36W T8 0.08
58W
T8 0.07
8W T5 0.28
11W PLS 0.28
13W
PL 0.23
16W 2D 0.20
18W T8/PL 0.15
24/26W PL 0.14
28W 2D 0.14
36W
T8/PL 0.10
38W 2D 0.12
40W PL0.15
55W
PL0.10
58W T8 0.09
70W T8 0.08
14W T5 0.25
21W T5 0.20
28W
T5 0.17
35W T5 0.17


Mains Supply
230-240V 50/60Hz


Supply Load
Less
than 50 mA


Charging Current
0.17
~ 0.3 A


Discharge Current
1.2 A
Nominal


Operating
Frequency
20 ~
50 Khz


Ambient Temperature
Range
0 -
50℃


Max. Module
Temp.
Tc max = 75℃ (Centre of Module side)
Based on the
ICEL1001 calculation method, the life is more than 70,000 hours at Tlife of 50℃
measured at the centre of the module side.


Max. Continuous cell
temp for 4 years life
55℃


Standards
EN60924 / EN61347-2-22


Dimension Fixing
Centres
H 30mm
x W 40mm x L 215mm


Weight (inc.
battery)
0.9 kg
1.0kg
1.0kg
1.10kg
1.10kg

Company: WEICO (ASIA) INDUSTRIES LTD.